Equipment Cleaning Guide

1. Lamp
a. Disinfection of metal and glass surfaces:

Make sure to clean and disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits. Wipe the surface thoroughly with a 70% isopropyl alcohol solution containing 30% pure water and 70% (99.9% chemically pure) isopropyl using a soft cloth (microfibre cloth) soaked in the solution and then wipe it dry with a dry cloth.
or
When using an alcohol-, chlorine- and solvent-free disinfectant solution, wipe the surface thoroughly using a soft cloth (microfibre cloth) soaked in the solution, and after the exposure time to the agent, 15 to 30 minutes later, remove the disinfectant from the surface using a wet cloth.

b. Disinfection of plastic, rubber, wood and textile surfaces:

Make sure to disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits.
When using an alcohol-, chlorine- and solvent-free disinfectant solution, wipe the surface thoroughly using a soft cloth (microfibre cloth) soaked in the solution, and after the exposure time to the agent, 15 to 30 minutes later, remove the disinfectant from the surface using a wet cloth.
When using an ozone generator, follow the instructions in the user manual, place the equipment indoors and, if an item has a carrying box, open it, making sure that the ozone gas gets everywhere. Ozone is a general disinfectant solution for all equipment.
Inquire and consult us about other disinfectants and disinfecting equipment.

2. Grip
a. Disinfection of metal and glass surfaces:

Make sure to clean and disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits.
Wipe the surface thoroughly with a 70% isopropyl alcohol solution containing 30% pure water and 70% (99.9% chemically pure) isopropyl using a soft cloth (microfibre cloth) soaked in the solution and then wipe it dry with a dry cloth.
or
When using an alcohol-, chlorine- and solvent-free disinfectant solution, wipe the surface thoroughly using a soft cloth (microfibre cloth) soaked in the solution, and after the exposure time to the agent, 15 to 30 minutes later, remove the disinfectant from the surface using a wet cloth.

b. Disinfection of plastic, rubber, wood and textile surfaces:

Make sure to disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits.
When using an alcohol-, chlorine- and solvent-free disinfectant solution, wipe the surface thoroughly using a soft cloth (microfibre cloth) soaked in the solution, and after the exposure time to the agent, 15 to 30 minutes later, remove the disinfectant from the surface using a wet cloth. When using an ozone generator, follow the instructions in the user manual, place the equipment indoors and, if an item has a carrying box, open it, making sure that the ozone gas gets everywhere. Ozone is a general disinfectant solution for all equipment.
Inquire and consult us about other disinfectants and disinfecting equipment.

3. Camera and video
a. Disinfection of metal and glass surfaces:

Make sure to clean and disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits or other mechanical defects.
For glass surfaces, make sure to use as soft microfibre or paper towels as possible. In the case of glass, pay special attention to the fact that you are disinfecting a very sensitive surface, which is extremely vulnerable and even a small scratch can cause serious damage.
Wipe the surface thoroughly with a 70% isopropyl alcohol solution containing 30% pure water and 70% (99.9% chemically pure) isopropyl using a soft cloth (microfibre cloth) slightly soaked in the solution and then wipe it dry with a dry cloth.

b. Disinfection of plastic, rubber, wood and textile surfaces:

Make sure to clean and disinfect electrical equipment only when it is not in operation and is de-energised, paying special attention to the external connectors and connection points of such equipment in order to avoid electrical faults and short circuits or other mechanical defects.
When using an alcohol-, chlorine- and solvent-free disinfectant solution, wipe the surface thoroughly using a soft cloth (microfibre cloth) soaked in the solution, and after the exposure time to the agent, 15 to 30 minutes later, remove the disinfectant from the surface using a wet cloth.
When using an ozone generator, follow the instructions in the user manual, place the equipment indoors and, if an item has a carrying box, open it, making sure that the ozone gas gets everywhere. Ozone is a general disinfectant solution for all equipment.
Inquire and consult us about other disinfectants and disinfecting equipment.